Installation guide - Under roofing

> Download : Installation guide.

Under rafters Panelling finish

Application

  • Unroll the ATI insulator horizontally under the rafters starting at the top of the roof.
  • Staple the ATI insulator on the ridge purlin with a turnback of at least 5 cm.
  • Staple the ATI insulator beneath the rafters up to the next purlin without forgetting to make
  • a turnback of at least 5 cm on the latter.
  • Proceed in the same way form the middle purlin to the lower purlin.
  • Join the overlap between each width with aluminium adhesive.
  • Fix a frame of brace-laths on the rafters and purlins, to create an air space.
  • Fix the panelling on the brace-laths.

Recommandations

  • Use 16 mm staples (galvanized or stainless steel).
  • Clean the joins with a dry and clean cloth before applying the adhesive.
  • Use an adhesive especially adapted to the insulation (aluminium adhesive of 75 mm or
  • polyester adhesive of 100 mm).
  • Respect the ventilation (inert-air space between the ATI insulator and the panelling).
  • To avoid thermal bridges, fix a brace-lath on the lower purlin and the middle purlins.
  • The dimensions of the brace-laths have to be in accordance with the thickness of the insulation,
  • to preserve a sufficient air space between the ATI insulator and the panelling.



Under rafters - Plasterboard finish

1st case : with cutting in insulation

Application

  • Fix the suspension posts on the rafters.
  • Unroll the ATI insulator horizontally under the rafters starting at the top of the roof.
  • Slit the ATI insulatorwith a craft knife to allow each suspension post to pass through.
  • Close again the cutting with the ATI adhesive.
  • Staple the ATI insulator on the ridge purlin with a turnback of at least 5cm.
  • Staple the ATI insulator beneath the rafters up to the next purlin without forgetting to make
  • a turnback of at least 5cm on the latter.
  • Proceed in the same way from the middle purlin to the lower purlin.
  • Join the overlap between each width with aluminium adhesive.
  • Fit the metallic rails onto the suspension posts.
  • Screw the plasterboard onto the metallic rails.

Recommandations

  • Use 16mm staples (galvanized or stainless steel).
  • Clean the joins with a dry and clean cloth before applying the adhesive.
  • Use an adhesive especially adapted at the insulation (aluminium adhesive of 75mm or
  • polyester adhesive of 100mm).
  • To avoid thermal bridges, fix a brace-lath on the lower purlin and the middle purlins.

2nd case : without cutting in insultation

Application

  • Unroll the ATI insulator horizontally under the rafters starting at the top of the roof.
  • Staple the ATI insulator on the ridge purlin with a turnback of at least 5cm.
  • Staple the ATI insulator beneath the rafters up to the next purlin without forgetting to make a turnback of at least 5cm on the latter.
  • Join the overlap between each width with aluminium adhesive.
  • Fit the semi-rafters 60 x 40 on the rafters.
  • Screw the suspension posts on the semi-rafters.
  • Fit the metallic rails onto the suspension posts.
  • Screw the plasterboard onto the metallic rails.

Recommandations

  • Use 16mm staples (galvanized or stainless steel).
  • Clean the joins with a dry and clean cloth before applying the adhesive.
  • Use an adhesive especially adapted to the insulation (aluminium adhesive of 75mm or polyester adhesive of 100mm).
  • To avoid thermal bridges, fix a brace-lath on the lower purlin and the middle purlins.